Part Number Hot Search : 
TSM69 2KBP08M EL6248CU LIS33 52AMI11L B80NF5 DC6VC C78L05CD
Product Description
Full Text Search
 

To Download CX-411 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  fiber sensors laser sensors photoelectric sensors micro photoelectric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire-saving systems measurement sensors static control devices laser markers photoelectric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 231 related information compact photoelectric sensor ampli er built-in cx-400 series world standard photoelectric sensors full line up 116 models! wide variety of 116 models you can nd your desired sensors among the cx-400 series because of their high basic performance, superior cost performance, and wide variation of types. strong against oil and coolant liquids the lens material for the thru-beam type, retrore ective type (excluding the cx-48 ) and the diffuse re ective type are made of a strong acrylic that resists the harmful effects of coolants. these sensors can be used with con dence even around metal processing machinery that disperses oil mists. the protection mechanism also conforms to ip67 (iec). cx-41 notes: 1) the adjustable range re ective type includes the cable type and m8 connector type only. 2) the adjustable range re ective type includes the 2 m 6.562 ft cable type (standard) only. conforming to emc directive ul recognition pnp output type available light intensity monitor interference prevention cable length of cable type (note 2) output connecting method (note 1) 0.5 m 1.640 ft , 2 m 6.562 ft , 5 m 16.404 ft cable type, m8 plug-in connector type, m12 pigtailed type npn, pnp 15 m 49.213 ft 5 m 16.404 ft 3 m 9.843 ft 0.1 to 2 m 0.328 in 6.562 in 800 mm 9.843 in 50 to 500 mm 1.969 to 19.685 in 300 mm 11.811 in 70 to 200 mm 2.756 to 7.874 in 10 m 32.808 ft 100 mm 3.937 in 20 to 300 mm 0.787 to 11.811 in 15 to 100 mm 0.591 to 3.937 in 2 to 50 mm 0.079 to 1.969 in 2 to 50 mm 0.079 to 1.969 in thru-beam (long sensing range) thru-beam retroreflective (long sensing range) retroreflective (with polarizing filters) retroreflective (for transparent object sensing) retroreflective (for transparent object sensing) diffuse reflective (800 mm 9.843 in type) diffuse reflective (300 mm 11.811 in type) diffuse reflective (100 mm 3.937 in type) diffuse reflective (narrow-view type) adjustable range reflective adjustable range reflective adjustable range reflective adjustable range reflective (small spot) type sensing range a strong, ethanol resistant polycarbonate was used for the front and display covers. safe even for installing near food processing machinery that disperses ethanol based detergents. the protection mechanism also conforms to ip67 (iec). strong against ethanol cx-44 caution: set the cx-48 so that cleaning liquid will not get on to the attached re ector. general terms and conditions ............. p.1 sensor selection guide ......p.11~ / p.229~ korea?s s-mark ........................... p.1034~ ms-aj / / chx-sc2 ..............p.799 / / p.800 glossary of terms / general precautions .... p.983 ~ / p.986 ~ certified (some models only) http://www.sunx.com sunx website
fiber sensors laser sensors photoelectric sensors micro photoelectric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire-saving systems measurement sensors static control devices laser markers photoelectric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 232 hardly affected by color strong infrared beam the longest in its class, it realizes a 15 m 49.213 ft long-distance sensing range. remarkable penetrating power enables applications such as package content detection. (note) basic performance can sense differences as small as 0.4 mm 0.016 in , with hysteresis of 2 % or less an advanced optical system provides sensing performance that is 2.5 times approx. than conventional models. even ultra-small differences of 0.4 mm 0.016 in can be detected accurately. cx-412 note: when sensing utilizing penetrating power, make sure to verify using the actual sensor. cx-441/443 2.5 times the 2 . 5 t i m e s t h e sensing capability! s e n s i n g c a p a b i l i t y ! height differences of as little as 0.4 mm 0.016 in can be detected at a setting distance of 20 mm 0.787 in 30 % higher 3 0 % h i g h e r sensing capability s e n s i n g c a p a b i l i t y retrore ective type with polarizing lters built-in polarizing lters ensure stable sensing even on a specular object. cx-491 cx-441/443 c x - 4 9 1 cx-491 the difference in sensing ranges is 1% or less between non-glossy white paper with a setting distance of 50 mm 1.969 in and non-glossy gray paper with a brightness level of 5. out of position slit mask CX-411 applications detecting out of position tape feeder cassette detecting objects in places that have a lot of dust or clouds of particles passage con rmation of object on a conveyor belt detecting transparent glass bottles small tablet sensing biscuit sensing c x - 4 1 2 cx-412 c x - 4 9 1 cx-491 cx-481 cx-441 cx-443 both black and white objects can be sensed at the same distances. no adjuster control is needed, even when products of different colors are moving along the production line. p.250 ~ dimensions p.248 ~ precautions for proper use p.243 ~ sensing characteristics p.242 i/o circuit diagrams p.240 ~ specifications p.236 ~ order guide
fiber sensors laser sensors photoelectric sensors micro photoelectric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire-saving systems measurement sensors static control devices laser markers selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 233 compact photoelectric sensor cx-400 series photoelectric sensors introducing the transparent object sensing type sensor our unique optical system and transparent object sensing circuitry provide stable sensing of even thinner transparent objects than the conventional models. cx-48 c x - 4 8 2 cx-482 twice the t w i c e t h e sensing range! s e n s i n g r a n g e ! twice the sensing range! sensing object sensing object size (mm in ) 50 1.969 ?50 ?1.969 ? = 50 1.969 50 1.969 50 1.969 50 1.969 50 1.969 50 1.969 ?66 ?2.598 t = 0.7 0.028 t = 1.3 0.051 t = 1.0 0.039 t = 0.9 0.035 t = 10 m 0.394 mil t = 20 m 0.787 mil t = 30 m 1.181 mil transparent objects detectable with cx-48 (typical examples) reflector setting range cx-481 : 300 to 500 mm 11.811 to 19.685 in , cx-482 : 1 to 2 m 3.281 to 6.562 ft [with the rf-230 reflector at the optimum condition (note)] each object should pass across the beam at the center between the sensor and the reflector. ?: length of cylindrical glasses t: thickness of sensing object note: the optimum condition is defined as the condition in which the sensitivity level is set such that the stability indicator just lights up when the object is absent. glass sheet cylindrical glass acrylic board styrol (floppy case) food wrapping film cigarette case film vinyl sack pet bottle (500m?) strong on dust and dirt because the light source is an infrared light, it is strong on dust and dirt compared to the red beam type. environmental resistance strong even in cold environments stable performance can be maintained even in environments of ?25 c ?13 f . strong against noise cx-412 inverter motor fluorescent light tube signi cantly stronger against inverter light and other extraneous light as well as high frequency and electromagnetic noise generated by high-pressure inverter motors and other devices. less power consumed the cx-400 series sensors achieve a maximum of approx. 55 % the power consumption of conventional sensors. contributes to preserving the environment. a maximum 45 % reduction compared to conventional sensors!! long sensing range of 5 m 16.404 ft a long 5 m 16.404 ft sensing range is possible with the red led type that is easy to align with the beam axis. can be used for wide automatic door shutters. cx-493 basic performance
fiber sensors laser sensors photoelectric sensors micro photoelectric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire-saving systems measurement sensors static control devices laser markers selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 234 photoelectric sensors mounting the bright spot makes beam axis alignment easy these sensors realize a high luminance red spot that provides bright visibility. the sensing position can be checked at a glance. because the cx-441 sensor has the smallest spot in its class ?2 mm ?0.079 in approx., even the minutest object can be accurately detected. cx-44 great visibility approx. ?2 mm ?0.079 in high luminance spot cx-441 beam axis alignment made easy with a high luminance spot beam these sensors realize a high luminance red led spot that provides bright visibility enabling the sensing position to be checked at a glance. because it has the smallest spot in its class, ?2 mm ?0.079 in approx., even the minutest object can be accurately detected. cx-423 great visibility approx. ?2 mm ?0.079 in high luminance spot (at setting distance 100 mm 3.937 in ) cx-423 reduction of volume adjustment labor because these sensors possess many variations depending on the sensing range, enables you to make optimal volume adjustment easily. operability can be used for sensing minute differences equipped with a 5-turn adjuster so that even challenging range settings can be handled with ease. cx-42 cx-422 : 800 mm 31.496 in cx-421 : 300 mm 11.811 in cx-424 : 100 mm 3.937 in cx-423 : 70 to 200 mm 2.756 to 7.874 in narrow-view type less processing m8 plug-in connector type and m12 pigtailed type are available. this contributes to less time spent in setting up. in addition, cable types are available with cable lengths of 0.5 m 1.640 ft , 2 m 6.562 ft and 5 m 16.404 ft . this results in less wastage. varieties select from 2 spot diameters as per the application within the choice of 50 mm 1.969 in sensing range sensors, we offer small spot approx. ?2 mm ?0.079 in type optimal for detecting minute object and large approx. ?6.5 mm ?0.256 in spot type capable of sensing object covered with holes and grooves. cx-441/443 5 m 16.404 ft 2 m 6.562 ft 0.5 m 1.640 ft cable type no unnecessary cables or terminal blocks m12 pigtailed type straight m8 plug-in connector type elbow straight great maintainability 2 m 6.562 ft / 5 m 16.404 ft () 2 m 6.562 ft / 5 m 16.404 ft () 2 m 6.562 ft / 5 m 16.404 ft () cx-443 spot diameter: ?6.5 mm ?0.256 in approx. detection of presence / absence of objects ignores minute holes and accurately detects objects. cx-441 spot diameter: ?2 mm ?0.079 in approx. [positioning] detects minute holes.
fiber sensors laser sensors photoelectric sensors micro photoelectric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire-saving systems measurement sensors static control devices laser markers selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 235 compact photoelectric sensor cx-400 series photoelectric sensors bgs / fgs functions make even the most challenging settings possible! for details on the operation of the bgs / fgs functions, refer to p.249 , ? bgs / fgs functions ? of ? precautions for proper use ?. functions cx-44 fgs (foreground suppression) function light received at position a light is not received at position b, so a object is judged to be present light received at position b for glossy object f o r g l o s s y o b j e c t object absent o b j e c t a b s e n t off in this condition only o f f i n t h i s c o n d i t i o n o n l y on in all other conditions o n i n a l l o t h e r c o n d i t i o n s the sensor judges that an object is present when no light is received at position b of the light-receiving element (2- segment element). accordingly, even objects that are glossy can be sensed. this is useful if the object and background are close together, or if the object being sensed is glossy. conveyor conveyor conveyor a lens emitting element on on off b setting distance a conveyor or other back-ground must be present object present o b j e c t p r e s e n t setting distance object moving object in the back background on off light received at element b, or light not received element b ( light received at element a ) element a bgs (background suppression) function the sensor judges that an object is present when light is received at position a of the light-receiving element (2-segment element). this is useful if the object and background are far apart. the distance adjustment method is the same as the conventional adjustment method for adjustable range reflective type sensors. less resources used based on environmental considerations, simpli ed packaging is used in order to reduce waste. in addition, the bag is made from polyethylene which produces no toxic gases even when burned. others strong against interference the interference prevention function lets two sensors to be mounted close together precisely. interference prevention filter (optional) thru-beam type only CX-411 automatic interference prevention function retroreflective type diffuse reflective type adjustable range reflective type not affected if the background color changes or someone passes behind the conveyor. unaffected by gloss, color or uneven surfaces when sensing objects present on a conveyor belt. the bgs function is best suited for the following case background not present when object and background are separated the fgs function is best suited for the following case background present when object and background are close together when the object is glossy or uneven bgs fgs
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 236 order guide type appearance sensing range model no. (note 1) emitting element npn output pnp output thru-beam 10 m 32.808 ft CX-411 CX-411-p red led long sensing range 15 m 49.213 ft cx-412 cx-412-p infrared led retrore ective with polarizing lters 3 m 9.843 ft (note 2) cx-491 cx-491-p red led long sensing range 5 m 16.404 ft (note 2) cx-493 cx-493-p for transparent object sensing 50 to 500 mm 1.969 to 19.685 in (note 2) cx-481 cx-481-p infrared led 0.1 to 2 m 0.328 to 6.562 ft (note 2) cx-482 cx-482-p diffuse re ective 100 mm 3.937 in cx-424 cx-424-p infrared led 300 mm 11.811 in cx-421 cx-421-p 800 mm 31.496 in cx-422 cx-422-p narrow-view 70 to 200 mm 2.756 to 7.874 in cx-423 cx-423-p red led adjustable range re ective small spot 2 to 50 mm 0.079 to 1.969 in cx-441 cx-441-p red led cx-443 cx-443-p 15 to 100 mm 0.591 to 3.937 in cx-444 cx-444-p 20 to 300 mm 0.787 to 11.811 in cx-442 cx-442-p note: mounting bracket is not supplied with the sensor. please select from the range of optional sensor mounting brackets. notes: 1) the model no. with suf x ? e ? shown on the label af xed to the thru-beam type sensor is the emitter, ? d ? shown on the label is the receiver. (e.g.) emitter of CX-411 : CX-411e , receiver of CX-411 : CX-411d 2) the sensing range of the retrore ective type sensor is speci ed for the rf-230 re ector. the sensing range represents the actual sensing range of the sensor. the sensing ranges itemized in ?a? of the table below may vary depending on the shape of sensing object. be sure to che ck the operation with the actual sensing object. setting range of the reflector: b sensing object sensing range: a sensor reflector cx-491 cx-493 cx-481 cx-482 a 0 to 3 m 0 to 9.843 ft 0 to 5 m 0 to16.404 ft 50 to 500 mm 1.969 to 19.685 in 0.1 to 2 m 0.328 to 6.562 ft b 0.1 to 3 m 0.328 to 9.843 ft 0.1 to 5 m 0.328 to 16.404 ft 100 to 500 mm 3.937 to 19.685 in 0.8 to 2 m 2.625 to 6.562 ft
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 237 compact photoelectric sensor cx-400 series order guide 0.5 m 1.640 ft / 5 m 16.404 ft cable length types 0.5 m 1.640 ft / 5 m 16.404 ft cable length types (standard: 2 m 6.562 ft ) are also available. when ordering this type, suf x ? -c05 ? for the 0.5 m 1.640 ft cable length type, ? -c5 ? for the 5 m 16.404 ft cable length type to the model no. (please note that 0.5 m 1.640 ft cable length type and 5 m 16.404 ft cable length type are not available for cx-44 .) (e.g.) 0.5m 1.640 ft cable length type of CX-411-p is ? CX-411-p-c05 ? 5 m 16.404 ft cable length type of CX-411-p is ? CX-411-p-c5 ? m8 plug-in connector type, m12 pigtailed type m8 plug-in connector type and m12 pigtailed type are also available. when ordering this type, suf x ? -z ? for the m8 connector type, ? -j ? for the m12 pigtailed type to the model no. (please note that m12 pigtailed type is not available for cx-44 .) (e.g.) m8 connector type of CX-411-p is ? CX-411-p-z ? m12 pigtailed type of CX-411-p is ? CX-411-p-j ? mating cable (2 cables are required for the thru-beam type.) ? type model no. cable length description for m8 plug-in connector type straight cn-24a-c2 2 m 6.562 ft can be used with all models cn-24a-c5 5 m 16.404 ft elbow cn-24al-c2 2 m 6.562 ft cn-24al-c5 5 m 16.404 ft for m12 pigtailed type 2-core cn-22-c2 2 m 6.562 ft for thru-beam type emitter (2-core) cn-22-c5 5 m 16.404 ft 4-core cn-24-c2 2 m 6.562 ft can be used with all models cn-24-c5 5 m 16.404 ft package without re ector npn output type: cx-491-y pnp output type: cx-491-p-y accessory rf-230 (re ector) ? mating cable cn-24a-c2 cn-24a-c5 ? cn-24al-c2 cn-24al-c5 ? cn-22-c2, cn-22-c5 cn-24-c2, cn-24-c5 ? 31.4 mm 1.236 in ?4 mm ?0.157 in ?9 mm ?0.354 in 23.1 mm 0.909 in ?9 mm ?0.354 in 20.5 mm 0.807 in ?4 mm ?0.157 in 300 mm 11.811 in ?14 mm ?0.551 in ?5 mm ?0.197 in
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 238 designation model no. slit size sensing range min. sensing object slit sensor slit on one side slit on both sides slit on one side slit on both sides round slit mask for thru-beam type sensor only os-cx-05 CX-411 ?0.5 mm ?0.020 in 400 mm 15.748 in 20 mm 0.787 in ?12 mm ?0.472 in ?0.5 mm ?0.020 in cx-412 600 mm 23.622 in 30 mm 1.181 in os-cx-1 CX-411 ?1 mm ?0.039 in 900 mm 35.433 in 100 mm 3.937 in ?12 mm ?0.472 in ?1 mm ?0.039 in cx-412 1.35 m 4.429 ft 150 mm 5.906 in ?1.5 mm ?0.059 in os-cx-2 CX-411 ?2 mm ?0.079 in 2 m 6.562 ft 400 mm 15.748 in ?12 mm ?0.472 in ?2 mm ?0.079 in cx-412 3 m 9.843 ft 600 mm 23.622 in ?3 mm ?0.118 in rectangular slit mask for thru-beam type sensor only os-cx-056 CX-411 0.5 6 mm 0.020 0.236 in 2 m 6.562 ft 400 mm 15.748 in ?12 mm ?0.472 in 0.5 6 mm 0.020 0.236 in cx-412 3 m 9.843 ft 600 mm 23.622 in os-cx-16 CX-411 1 6 mm 0.039 0.236 in 3 m 9.843 ft 1 m 3.281 ft ?12 mm ?0.472 in 1 6 mm 0.039 0.236 in cx-412 4.5 m 14.764 ft 1.5 m 4.921 ft os-cx-26 CX-411 2 6 mm 0.079 0.236 in 5 m 16.404 ft 2 m 6.562 ft ?12 mm ?0.472 in 2 6 mm 0.079 0.236 in cx-412 7.5 m 24.606 ft 3 m 9.843 ft options designation model no. sensing range min. sensing object interference prevention lter for cx-441 only pf-cx4-v (vertical) 2 pcs. per set 5 m 16.404 ft (note 1) ?12 mm ?0.472 in (note 1) pf-cx4-h (horizonal) 2 pcs. per set 5 m 16.404 ft (note 1) ?12 mm ?0.472 in (note 1) re ector for retrore ective type sensor only rf-210 cx-491 1 m 3.281 ft (note 2) ?30 mm ?1.181 in cx-493 1.5 m 4.921 ft (note 2) cx-481 ? cx-482 0.1 to 0.6 m 0.328 to 1.969 ft (note 2) rf-220 cx-491 1.5 m 4.921 ft (note 2) ?35 mm ?1.378 in cx-493 3 m 9.843 ft (note 2) cx-481 50 to 300 mm 1.969 to 11.811 in (note 2) cx-482 0.1 to 1.3 m 0.328 to 4.265 ft (note 2) round slit mask os-cx- fitted on the front face of the sensor with one-touch. rectangular slit mask os-cx- fitted on the front face of the sensor with one-touch. interference prevention lter pf-cx4-v ? pf-cx4-h ? two sets of cx-441 can be mounted close together. round slit mask (stainless steel) rectangular slit mask (stainless steel) re ector rf-210 ? rf-220 ? interference prevention filter 33.3 mm 1.311 in 11 mm 0.433 in 12.8 mm 0.504 in 35.3 mm 1.390 in 8.3 mm 0.327 in 42.3 mm 1.665 in notes: 1) value when attached to both sides. 2) set the distance between the cx-491 /493 and the re ector to 0.1 m 0.328 ft or more. however, see the table below for cx-48 . the sensing range ?a? may vary depending on the shape of sensing object. be sure to check the operation with the actual sensing object. setting range of the reflector: b sensing object sensing range: a sensor reflector model no. ab sensor re ector cx-481 50 to 300 mm 1.969 to 11.811 in 100 to 300 mm 3.937 to 11.811 in cx-482 0.1 to 1.3 m 0.328 to 4.265 ft 0.5 to 1.3 m 1.640 to 4.265 ft rf-210 0.1 to 0.6 m 0.328 to 1.969 ft 0.3 to 0.6 m 0.984 to 1.969 ft
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 239 compact photoelectric sensor cx-400 series options designation model no. description re ector mounting bracket ms-rf21-1 protective mounting bracket for rf-210 it protects the re ector from damage and maintains alignment. ms-rf22 for rf-220 ms-rf23 for rf-230 re ective tape rf-11 sensing range (note 4): 0.5 m 1.640 ft [ cx-491 ] 0.8 m 2.625 ft [ cx-493 ] ? ambient temperature: ?25 to +50 c ?13 to +122 f ambient humidity: 35 to 85 % rh notes keep the tape free from stress. if it is pressed too much, its capability may deteriorate. do not cut the tape. it will deteriorate the sensing performance. ? ? ? ? rf-12 sensing range (note 4): 0.7 m 2.297 ft [ cx-491 ] 1.2 m 3.937 ft [ cx-493 ] 0.1 to 0.6 m 0.328 to 1.969 ft [ cx-482 ] ? rf-13 sensing range (note 4): 0.5 m 1.640 ft [ cx-491 ] 0.8 m 2.625 ft [ cx-493 ] ? ambient temperature: ?25 to +55 c ?13 to +131 f ambient humidity: 35 to 85 % rh ? ? sensor mounting bracket (note 1) ms-cx2-1 foot angled mounting bracket it can also be used for mounting rf-210 . the thru-beam type sensor needs two brackets. ms-cx2-2 foot biangled mounting bracket it can also be used for mounting rf-210 . ms-cx2-4 protective mounting bracket ms-cx2-5 back biangled mounting bracket ms-cx-3 back angled mounting bracket universal sensor mounting stand (note 2) ms-aj1 horizontal mounting type basic assembly ms-aj2 vertical mounting type ms-aj1-a horizontal mounting type lateral arm assembly ms-aj2-a vertical mounting type ms-aj1-m horizontal mounting type assembly for re ector ms-aj2-m vertical mounting type sensor checker (note 3) chx-sc2 it is useful for beam alignment of thru-beam type sensors. the optimum receiver position is given by indicators, as well as an audio signal. re ector mounting bracket ms-rf23 ? re ective tape sensor mounting bracket ms-rf21-1 ? ms-rf22 ? two m3 (length 12 mm 0.472 in ) screws with washers are attached. two m3 (length 8 mm 0.315 in ) screws with washers are attached. two m4 (length 10 mm 0.394 in ) screws with washers are attached. rf-11 ? rf-12 ? rf-13 ? 30 mm 1.181 in 0.7 mm 0.028 in 8 mm 0.315 in 30 mm 1.181 in 25 mm 0.984 in 0.7 mm 0.028 in 30 mm 1.181 in 30mm 1.181 in 0.5mm 0.020 in ms-cx2-1 ? ms-cx2-2 ? ms-cx2-4 ? ms-cx2-5 ? ms-cx-3 ? sensor checker two m3 (length 12 mm 0.472 in ) screws with washers are attached. two m3 (length 12 mm 0.472 in ) screws with washers are attached. two m3 (length 14 mm 0.551 in ) screws with washers are attached. two m3 (length 12 mm 0.472 in ) screws with washers are attached. two m3 (length 12 mm 0.472 in ) screws with washers are attached. chx-sc2 ? leve l pow er chx-sc2 sensor checker notes: 1) the plug-in connector type sensor does not allow use of some sensor mounting brackets because of the protrusion of the connector. 2) refer to p.799 for details of the universal sensor mounting stand. 3) refer to p.800 for details of the sensor checker chx-sc2 . 4) set the distance between the sensor and the re ective tape to 0.1 m 0.328 ft ( cx-482 : 0.4 m 1.312 ft ) or more. 360 45 45 swivel: 360 rotation height adjustment: 150 mm 5.906 in approx. forward / back adjustment: 130 mm 5.118 in approx. angle adjustment: 45 mounting hole for m6 screw 45 45 angle adjustment: 45 forward / back adjustment: 130 mm 5.118 in approx. swivel: 360 rotation 360 height adjustment: 150 mm 5.906 in approx. mounting hole for m6 screw universal sensor mounting stand ms-aj2 ? ms-aj2-a ? ms-aj2-m ? 45 45 elevation angle: 45 mounting hole for m6 screw height adjustment: 150 mm 5.906 in approx. swivel: 360 rotation height adjustment: 150 mm 5.906 in approx. mounting hole for m6 screw 45 45 elevation angle: 45 swivel: 360 rotation ms-aj1 ? ms-aj1-a ? ms-aj1-m ? 45 45 elevation angle: 45 swivel: 360 rotation mounting hole for m6 screw height adjustment: 150 mm 5.906 in approx. swivel: 360 rotation 45 45 elevation angle: 45 height adjustment: 150 mm 5.906 in approx. mounting hole for m6 screw with the lateral arm, the sensor can sense from above a production line. with the lateral arm, the sensor can sense from above a production line.
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 240 notes: 1) where measurement conditions have not been speci ed precisely, the conditions used were an ambient temperature of +23 c +73.4 f . 2) the sensing range and the sensing object of the retrore ective type sensor are speci ed for the rf-230 re ector. the sensing range represents the actual sensing range of the sensor. the sensing ranges itemized in ?a? of the table below may vary depending on the shape of se nsing object. be sure to check the operation with the actual sensing object. 3) the sensing range and the hysteresis of the diffuse re ective type sensor are speci ed for white non-glossy paper (200 200 mm 7.874 7.874 in ) as the object. 4) if slit masks (optional) are tted, an object of ?0.5 mm ?0.020 in (using round slit mask) can be detected. 5) make sure to con rm detection with an actual sensor before use. sensor reflector setting range of the reflector: b sensing object sensing range: a cx-491 cx-493 cx-481 cx-482 a 0 to 3 m 0 to 9.843 ft 0 to 5 m 0 to16.404 ft 50 to 500 mm 1.969 to 19.685 in 0.1 to 2 m 0.328 to 6.562 ft b 0.1 to 3 m 0.328 to 9.843 ft 0.1 to 5 m 0.328 to 16.404 ft 100 to 500 mm 3.937 to 19.685 in 0.8 to 2 m 2.625 to 6.562 ft specificactions type thru-beam retrore ective diffuse re ective long sensing range with polarizing lters long sensing range for transparent object sensing narrow-view model no. npn output CX-411 cx-412 cx-491 cx-493 cx-481 cx-482 cx-424 cx-421 cx-422 cx-423 item pnp output CX-411-p cx-412-p cx-491-p cx-493-p cx-481-p cx-482-p cx-424-p cx-421-p cx-422-p cx-423-p sensing range 10 m 32.808 ft 15 m 49.213 ft 3 m 9.843 ft (note 2) 5 m 16.404 ft (note 2) 50 to 500 mm 1.969 to 19.685 in (note 2) 0.1 to 2 m 0.328 to 6.562 ft (note 2) 100 mm 3.937 in (note 3) 300 mm 11.811 in (note 3) 800 mm 31.496 in (note 3) 70 to 200 mm 2.756 to 7.874 in (note3) sensing object ?12 mm ?0.472 in or more opaque object (note 4) ?50 mm ?1.969 in or more opaque, translucent or specular object (note 2, 5) ?50 mm ?1.969 in or more opaque or translucent object (note 2, 5) ?50 mm ?1.969 in or more transparent, translucent or opaque object (note 2, 5) opaque, translucent or transparent object (note 5) opaque, translucent or transparent object (note 5) min. sensing object: ?0.5 mm ?0.020 in copper wire hysteresis ? 15 % or less of operation distance (note 3) repeatability (perpendicular to sensing axis) 0.5 mm 0.020 in or less 1 mm 0.039 in or less 0.5 mm 0.020 in or less supply voltage 12 to 24 v dc 10 % ripple p-p 10 % or less current consumption emitter: 20 ma or less receiver: 20 ma or less emitter: 25 ma or less receiver: 20 ma or less 20 ma or less 25 ma or less 25 ma or less 20 ma or less output npn open-collector transistor maximum sink current: 100 ma applied voltage: 30 v dc or less (between output and 0 v) residual voltage: 1 v or less (at 100 ma sink current) 0.4 v or less (at 16 ma sink current) ? ? ? pnp open-collector transistor maximum source current: 100 ma applied voltage: 30 v dc or less (between output and +v) residual voltage: 1 v or less (at 100 ma source current) 0.4 v or less (at 16 ma source current) ? ? ? output operation switchable either light-on or dark-on short-circuit protection incorporated response time 1 ms or less operation indicator orange led (lights up when the output is on) (incorporated on the receiver for thru-beam type) stability indicator green led (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-bea m type) power indicator green led (lights up when the power is on) (incorporated on the emitter) ? sensitivity adjuster continuously variable adjuster (incorporated on the receiver for thru-beam type) automatic interference prevention function two units of sensors can be mounted close together with interference prevention lters. (sensing range: 5 m 16.404 ft ) ? incorporated (two units of sensors can be mounted close together.) environmental resistance protection ip67 (iec) (refer to p.984 for details of standards.) ambient temperature ? 25 to +55 c ?13 to +131 f (no dew condensation or icing allowed ), storage: ?30 to +70 c ?22 to +158 f ambient humidity 35 to 85 % rh, storage: 35 to 85 % rh ambient illuminance incandescent light: 3,000 ? x at the light-receiving face emc en 60947-5-2 voltage withstandability 1,000 v ac for one min. between all supply terminals connected together and enclosure insulation resistance 20 m , or more, with 250 v dc megger between all supply terminals connected together and enclosure vibration resistance 10 to 500 hz frequency, 1.5 mm 0.059 in amplitude (10 g max.) in x, y and z directions for two hours each shock resistance 500 m/s 2 acceleration (50 g approx.) in x, y and z directions for three times each emitting element (modulated) red led infrared led red led infrared led infrared led red led peak emission wavelength 680 nm 0.027 mil 870 nm 0.034 mil 680 nm 0.027 mil 650 nm 0.026 mil 870 nm 0.034 mil 860 nm 0.034 mil 645 nm 0.025 mil material enclosure: pbt (polybutylene terephthalate), lens: acrylic ( cx-48 : polycarbonate), indicator cover: acrylic ( cx-48 : polycarbonate) cable 0.2 mm 2 3-core (thru-beam type emitter: 2-core) cabtyre cable, 2 m 6.562 ft long cable extension extension up to total 100 m 328.084 ft is possible with 0.3 mm 2 , or more, cable (thru-beam type: both emitter and receiver). weight net weight emitter: 45 g approx., receiver: 50 g approx. 50 g approx. gross weight 100 g approx. 80 g approx. 60 g approx. accessory ? rf-230 (re ector): 1 pc. ?
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 241 compact photoelectric sensor cx-400 series notes: 1) where measurement conditions have not been speci ed precisely, the conditions used were an ambient temperature of +23 c +73.4 f . 2) the adjustable range stands for the maximum sensing range which can be set with the distance adjuster. the sensor can detect an object 2 mm 0.079 in [ cx-444 ( -p ): 15 mm 0.591 in , cx-442 ( -p ): 20 mm 0.787 in ], or more, away. 3) note that detection may be unstable depending on the mounting conditions or the sensing object. in the state that this product is mounted, be sure to check the operation with the actual sensing object. actual sensing range of the sensor: a sensing object adjustable range: b cx-441 / / 443 a 2 to 50 mm 0.079 to 1.969 in 15 to 100 mm 0.591 to 3.937 in 20 to 300 mm 0.787 to 11.811 in b 20 to 50 mm 0.787 to 1.969 in 20 to 100 mm 0.787 to 3.937 in 40 to 300 mm 1.575 to 11.811 in specificactions type adjustable range re ective small spot model no. npn output cx-441 cx-443 cx-444 cx-442 item pnp output cx-441-p cx-443-p cx-444-p cx-442-p adjustable range (note 2) 20 to 50 mm 0.787 to 1.969 in 20 to 100 mm 0.787 to 3.937 in 40 to 300 mm 1.575 to 11.811 in sensing range (with white non-glossy paper) 2 to 50 mm 0.079 to 1.969 in 15 to 100 mm 0.591 to 3.937 in 20 to 300 mm 0.787 to 11.811 in hysteresis 2 % or less of operation distance (with white non-glossy paper) 5 % or less of operation distance (with white non-glossy paper) repeatability along sensing axis: 1 mm 0.039 in or less, perpendicular to sensing axis: 0.2 mm 0.008 in or less (with white non-glossy paper) supply voltage 12 to 24 v dc 10 % ripple p-p 10 % or less current consumption 25 ma or less output npn open-collector transistor maximum sink current: 100 ma applied voltage: 30 v dc or less (between output and 0 v) residual voltage: 1 v or less (at 100 ma sink current) 0.4 v or less (at 16 ma sink current) ? ? ? pnp open-collector transistor maximum source current: 100 ma applied voltage: 30 v dc or less (between output and +v) residual voltage: 1 v or less (at 100 ma source current) 0.4 v or less (at 16 ma source current) ? ? ? output operation switchable either detection-on or detection-off short-circuit protection incorporated response time 1 ms or less operation indicator orange led (lights up when the output is on) stability indicator green led (lights up under stable operating condition) distance adjuster 5-turn mechanical adjuster sensing mode bgs / fgs functions switchable with wiring of sensing mode selection input automatic interference prevention function (note 3) incorporated environmental resistance protection ip67 (iec) (refer to p.984 for details of standards.) ambient temperature ?25 to +55 c ?13 to +131 f (no dew condensation or icing allowed ), storage: ?30 to +70 c ?22 to +158 f ambient humidity 35 to 85 % rh, storage: 35 to 85 % rh ambient illuminance incandescent light: 3,000 ? x at the light-receiving face emc en 60947-5-2 voltage withstandability 1,000 v ac for one min. between all supply terminals connected together and enclosure insulation resistance 20 m , or more, with 250 v dc megger between all supply terminals connected together and enclosure vibration resistance 10 to 500 hz frequency, 3 mm 0.118 in amplitude in x, y and z directions for two hours each shock resistance 500 m/s 2 acceleration (50 g approx.) in x, y and z directions for three times each emitting element red led (peak emission wavelength: 680 nm 0.027 mil , modulated) spot diameter ?2 mm ?0.079 in approx. (at 50 mm 1.969 in distance) ?6.5 mm ?0.256 in approx. (at 50 mm 1.969 in distance) ?9 mm ?0.354 in approx. (at 100 mm 3.937 in distance) 15 mm 0.591 in approx. (at 300 mm 11.811 in distance) material enclosure: pbt (polybutylene terephthalate), front cover: polycarbonate, indicator cover: polycarbonate cable 0.2 mm 2 4-core cabtyre cable, 2 m 6.562 ft long cable extension extension up to total 100 m 328.084 ft is possible with 0.3 mm 2 , or more, cable. weight net weight: 55 g approx., gross weight: 80 g approx.
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 242 i/o circuit and wiring diagrams i/o circuit diagram npn output type d tr z d *1 users circuit internal circuit 100 ma max. (pink / 2) sensing mode selection input (note 2, 3) (blue / 3) 0 v (brown / 1) +v (black / 4) output (note 1) load sensor circuit color code / connector pin no. of the plug-in connector type + C 12 to 24 v dc 10 % wiring diagram *1 load brown black (note 1) blue pink (note 2, 3) + C 12 to 24 v dc 10 % notes: 1) the emitter of the thru-beam type sensor does not incorporate the output. 2) sensing mode selection input is incorporated only for the cx-44 adjustable range re ective type. when using the cx-44 , be sure to wire the sensing mode selection input (pink / 2). 3) when the mating cable is connected to the plug-in connector type of cx-44 , its color is white. 1 * sensing mode selection input bgs function: connect to 0 v fgs function: connect to +v ? symbols ? d : reverse supply polarity protection diode z d : surge absorption zener diode tr : npn output transistor notes: 1) the emitter of the thru-beam type sensor does not incorporate the black wire. 2) the pink wire is incorporated only for the cx-44 adjustable range re ective type. when using the cx-44 , be sure to wire the pink wire. 3) when the mating cable is connected to the plug-in connector type of cx-44 , its color is white. connector pin position m8 plug-in connector type m12 pigtailed type notes: 1) the emitter of the thru-beam type sensor does not incorporate the output. 2) sensing mode selection input is incorporated only for the cx-44 adjustable range re ective type. when using the cx-44 , be sure to wire the sensing mode selection input (pink / 2). 24 1 +v 3 0 v output (note 1) sensing mode selection input (note 2) 2 1 +v 3 0 v 4 output (note 1) not connected 1 * sensing mode selection input bgs function: connect to 0 v fgs function: connect to +v ? pnp output type i/o circuit diagram wiring diagram tr z d d + *1 users circuit internal circuit 100 ma max. (pink / 2) sensing mode selection input (note 2, 3) (blue / 3) 0 v C 12 to 24 v dc 10 % (brown / 1) +v (black / 4) output (note 1) load sensor circuit color code / connector pin no. of the plug-in connector type *1 load brown black (note 1) blue pink (note 2, 3) + C 12 to 24 v dc 10 % notes: 1) the emitter of the thru-beam type sensor does not incorporate the output. 2) sensing mode selection input is incorporated only for the cx-44 -p adjustable range re ective type. when using the cx-44 -p , be sure to wire the sensing mode selection input (pink / 2). 3) when the mating cable is connected to the plug-in connector type of cx-44 , its color is white. 1 * sensing mode selection input bgs function: connect to 0 v fgs function: connect to +v ? symbols ? d : reverse supply polarity protection diode z d : surge absorption zener diode tr : pnp output transistor notes: 1) the emitter of the thru-beam type sensor does not incorporate the black wire. 2) the pink wire is incorporated only for the cx-44 -p adjustable range re ective type. when using the cx-44 -p , be sure to wire the pink wire. 3) when the mating cable is connected to the plug-in connector type of cx-44 , its color is white. connector pin position m8 plug-in connector type m12 pigtailed type notes: 1) the emitter of the thru-beam type sensor does not incorporate the output. 2) sensing mode selection input is incorporated only for the cx-44 -p adjustable range re ective type. when using the cx-44 -p , be sure to wire the sensing mode selection input (pink / 2). 24 output (note 1) 1 +v 3 0 v sensing mode selection input (note 2) 2 1 +v 3 0 v 4 output (note 1) not connected 1 * sensing mode selection input bgs function: connect to 0 v fgs function: connect to +v ?
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 243 compact photoelectric sensor cx-400 series sensing characteristics (typical) CX-411 thru-beam type parallel deviation angular deviation parallel deviation with round slit masks (?0.5 mm ?0.020 in ) parallel deviation with round slit masks (?1 mm ?0.039 in ) ? 200 0 200 400 400 15.748 7.874 7.874 15.748 0 5 16.404 10 32.808 left right center operating point ? (mm in ) setting distance l (m ft ) l emitter receiver 40 0 5 16.404 10 32.808 setting distance l (m ft ) 20 0 20 40 l receiver left right center operating angle ( ) emitter ? l receiver emitter slit on both sides 0 0.787 0.394 0.394 0.787 0 200 7.874 400 15.748 left right center operating point ? (mm in ) setting distance l (mm in ) 10 10 20 slit on one side 20 ? 400 15.748 800 31.496 setting distance l (mm in ) receiver emitter slit on one side slit on both sides l 40 20 0 0 20 40 1.575 0.787 0.787 1.575 left right center operating point ? (mm in ) parallel deviation with round slit masks (?2 mm ?0.079 in ) parallel deviation with rectangular slit masks (0.5 6 mm 0.020 0.236 in ) parallel deviation with rectangular slit masks (1 6 mm 0.039 0.236 in ) parallel deviation with rectangular slit masks (2 6 mm 0.079 0.236 in ) ? 0 1 3.281 2 6.562 setting distance l (m ft ) slit on one side slit on both sides receiver emitter l 100 50 0 50 100 3.937 1.969 1.969 3.937 left right center operating point ? (mm in ) ? ? 100 50 50 100 3.937 1.969 1.969 3.937 1 3.281 2 6.562 setting distance l (m ft ) center operating point ? (mm in ) (down) left right (up) slit on both sides horizontal direction horizontal direction vertical direction receiver receiver emitter emitter slit on one side vertical direction slit on one side horizontal direction slit on both sides vertical direction l l 0 0 ? ? slit on both sides horizontal direction slit on one side horizontal direction slit on one side vertical direction center operating point ? (mm in ) (down) left right (up) 0 7.874 3.937 7.874 2 6.562 3 9.843 4 13.123 emitter emitter horizontal direction vertical direction slit on both sides vertical direction 200 200 3.937 0 1 3.281 receiver l l receiver setting distance l (m ft ) 100 100 ? ? 6 19.685 8 26.247 setting distance l (m ft ) slit on one side horizontal direction slit on one side vertical direction 200 7.874 100 100 200 3.937 3.937 7.874 l receiver emitter vertical direction center operating point ? (mm in ) (down) left right (up) slit on both sides vertical direction 2 6.562 4 13.123 emitter l horizontal direction slit on both sides horizontal direction receiver 0 0 cx-412 thru-beam type parallel deviation parallel deviation with round slit masks (?0.5 mm ?0.020 in ) parallel deviation with round slit masks (?1 mm ?0.039 in ) angular deviation ? 500 0 500 1,000 1,000 39.370 19.685 19.685 39.370 0 5 16.404 10 32.808 15 49.213 20 65.617 left right center operating point ? (mm in ) setting distance l (m ft ) l emitter receiver 40 0 setting distance l (m ft ) 20 0 20 40 l receiver left right center operating angle ( ) emitter 5 16.404 10 32.808 15 49.213 20 65.617 ? l receiver emitter slit on both sides 0 3.937 1.969 1.969 3.937 0 200 7.874 400 15.748 600 23.622 800 31.496 left right center operating point ? (mm in ) setting distance l (mm in ) 50 50 100 slit on one side 100 ? setting distance l (m ft ) 0 0.5 1.640 1 3.281 1.5 4.921 2 6.562 receiver emitter slit on one side slit on both sides l 200 100 0 100 200 7.874 3.937 3.937 7.874 left right center operating point ? (mm in ) parallel deviation with rectangular slit masks (1 6 mm 0.039 0.236 in ) parallel deviation with round slit masks (?2 mm ?0.079 in ) parallel deviation with rectangular slit masks (0.5 6 mm 0.020 0.236 in ) parallel deviation with rectangular slit masks (2 6 mm 0.079 0.236 in ) ? 0 1 3.281 2 6.562 3 9.843 4 13.123 setting distance l (m ft ) slit on one side slit on both sides receiver emitter l 400 200 0 200 400 15.748 7.874 7.874 15.748 left right center operating point ? (mm in ) ? ? 0 1 3.281 2 6.562 3 9.843 4 13.123 400 200 0 200 400 15.748 7.874 7.874 15.748 setting distance l (m ft ) center operating point ? (mm in ) (down) left right (up) horizontal direction vertical direction receiver receiver emitter emitter slit on one side horizontal direction slit on one side vertical direction slit on both sides horizontal and vertical direction l l ? ? 400 200 0 200 400 15.748 7.874 7.874 15.748 slit on both sides horizontal and vertical direction center operating point ? (mm in ) (down) left right (up) 2 6.562 4 13.123 emitter emitter horizontal direction vertical direction 0 receiver l l receiver setting distance l (m ft ) slit on one side horizontal direction slit on one side vertical direction ? ? slit on both sides horizontal and vertical direction horizontal direction vertical direction 6 19.685 8 26.247 setting distance l (m ft ) 800 31.496 400 400 800 15.748 15.748 31.496 l receiver emitter center operating point ? (mm in ) (down) left right (up) 2 6.562 4 13.123 emitter l receiver 0 0 slit on one side vertical direction slit on one side horizontal direction
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 244 as the sensing object size becomes smaller than the standard size (white non-glossy paper 200 200 mm 7.874 7.874 in ), the sensing range shortens, as shown in the left graph. for plotting the left graph, the sensitivity has been set such that a 200 200 mm 7.874 7.874 in white non-glossy paper is just detectable at a distance of 300 mm 11.811 in . sensing characteristics (typical) cx-491 retrore ective type cx-493 retrore ective type parallel deviation angular deviation parallel deviation angular deviation cx-481 retrore ective type cx-482 retrore ective type angular deviation parallel deviation angular deviation parallel deviation correlation between sensing object size and sensing range sensing eld cx-424 diffuse re ective type correlation between sensing object size and sensing range sensing eld cx-421 diffuse re ective type as the sensing object size becomes smaller than the standard size (white non-glossy paper 200 200 mm 7.874 7.874 in ), the sensing range shortens, as shown in the left graph. for plotting the left graph, the sensitivity has been set such that a 200 200 mm 7.874 7.874 in white non-glossy paper is just detectable at a distance of 100 mm 3.937 in . ? 200 100 0 100 200 7.874 3.937 3.937 7.874 left center operating point ? (mm in ) 1 3.281 2 6.562 3 9.843 4 13.123 sensor reflector ( rf-230 ) setting distance l (m ft ) 0 right l 40 20 0 20 40 setting distance l (m ft ) 1 3.281 2 6.562 3 9.843 4 13.123 left right center operating angle ( ) 0 l reflector ( rf-230 ) reflector ( rf-230 ) sensor angular deviation reflector angular deviation l l sensor sensor sensor angular deviation reflector angular deviation ? 200 100 0 100 200 7.874 3.937 3.937 7.874 sensor reflector ( rf-230 ) l 2 6.562 4 13.123 6 19.685 8 26.247 0 left center operating point ? (mm in ) setting distance l (m ft ) right sensor l 2 6.562 4 13.123 6 19.685 8 26.247 0 sensor angular deviation l sensor reflector ( rf-230 ) sensor angular deviation 40 20 0 20 40 setting distance l (m ft ) left right center operating angle ( ) reflector angular deviation sensor angular deviation reflector angular deviation reflector ( rf-230 ) 1 3.281 2 6.562 0 sensor sensor sensor angular deviation reflector angular deviation 40 20 0 20 40 setting distance l (m ft ) left right center operating angle ( ) l l reflector ( rf-230 ) reflector ( rf-230 ) reflector angular deviation sensor angular deviation ? 200 100 0 100 200 7.874 3.937 3.937 7.874 sensor reflector ( rf-230 ) l 1 3.281 2 6.562 0 left center operating point ? (mm in ) setting distance l (m ft ) right l l sensor sensor 200 7.874 400 15.748 600 23.622 800 31.496 0 reflector ( rf-230 ) reflector ( rf-230 ) sensor angular deviation reflector angular deviation reflector angular deviation 40 20 0 20 40 left right center operating angle ( ) setting distance l (mm in ) sensor angular deviation ? 100 50 0 50 100 3.937 1.969 1.969 3.937 sensor reflector ( rf-230 ) l 200 7.874 400 15.748 600 23.622 800 31.496 0 left center operating point ? (mm in ) right setting distance l (mm in ) ? 20 10 0 10 20 0 0.787 0.394 0.394 0.787 setting distance l (mm in ) l sensor 200 200 mm 7.874 7.874 in white non-glossy paper left right center operating point ? (mm in ) 50 1.969 100 3.937 50 1.969 100 3.937 0 50 100 150 200 1.969 3.937 5.906 7.874 sensing range l (mm in ) sensor a a mm white non-glossy paper l white non-glossy paper side length a (mm in ) ? 40 20 0 20 40 0 100 3.937 200 7.874 400 15.748 1.575 0.787 0.787 1.575 300 11.811 setting distance l (mm in ) left right center operating point ? (mm in ) l sensor 200 200 mm 7.874 7.874 in white non- glossy paper 0 100 3.937 200 7.874 300 11.811 400 15.748 50 100 150 200 1.969 3.937 5.906 7.874 white non-glossy paper side length a (mm in ) sensor a a mm white non- glossy paper l sensing range l (mm in )
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 245 compact photoelectric sensor cx-400 series correlation between sensing object size and sensing range sensing eld cx-422 diffuse re ective type as the sensing object size becomes smaller than the standard size (white non-glossy paper 200 200 mm 7.874 7.874 in ), the sensing range shortens, as shown in the left graph. for plotting the left graph, the sensitivity has been set such that a 200 200 mm 7.874 7.874 in white non-glossy paper is just detectable at a distance of 800 mm 31.496 in . sensing characteristics (typical) cx-423 diffuse re ective type ? 40 20 0 20 40 1.575 0.787 0.787 1.575 500 19.685 1,000 39.370 setting distance l (mm in ) left right center operating point ? (mm in ) sensor 200 200 mm 7.874 7.874 in white non- glossy paper l 0 0 1.969 3.937 400 15.748 800 31.496 50 100 150 200 5.906 7.874 a a mm white non- glossy paper l sensor white non-glossy paper side length a (mm in ) sensing range l (mm in ) correlation between sensing object size and sensing range sensing eld as the sensing object size becomes smaller than the standard size (white non-glossy paper 200 200 mm 7.874 7.874 in ), the sensing range shortens, as shown in the left graph. for plotting the left graph, the sensitivity has been set such that a 200 200 mm 7.874 7.874 in white non-glossy paper is just detectable at a distance of 200 mm 7.874 in . ? 0.079 0.039 0.039 0.079 21012 0 100 3.937 200 7.874 n6 white setting distance l (mm in ) left right center operating point ? (mm in ) 200 200 mm 7.874 7.874 in non-glossy paper sensor l n6 white 0 100 3.937 200 7.874 1.969 3.937 a a mm non-glossy paper non-glossy paper side length a (mm in ) 5.906 7.874 50 100 150 200 l sensor sensing range l (mm in ) correlation between lightness and sensing range the sensing region is represented by oblique lines in the left gure. however, the sensitivity should be set with an enough margin because of slight variation in products. emitted beam n2 n4 n8 n6 100 3.937 200 7.874 n2 n5 n7 n9 n1 n4 n6 n8 n3 sensing region sensing range l (mm in ) dark light 0 lightness 250 9.843 200 7.874 150 5.906 50 1.969 0 100 3.937 110 4.331 ?5 mm ?0.197 in ?2.5 mm ?0.098 in ?2.2 mm ?0.087 in ?2 mm ?0.079 in ?4 mm ?0.157 in distance l (mm in ) visible spot range lightness shown on the left may differ slightly from the actual object condition.
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 246 cx-441 adjustable range re ective type sensing characteristics (typical) setting distance: 25 mm 0.984 in ? sensing elds emitted beam setting distance: 50 mm 1.969 in ? ? 2 0.079 02 0.079 4 0.157 right center operating point ? (mm in ) 4 0.157 0 10 0.394 20 0.787 30 1.181 40 1.575 50 50 mm 1.969 1.969 in non-glossy paper gray non-glossy paper lightness: 5 white non- glossy paper sensor l left setting distance l (mm in ) ? 4 0.157 2 0.079 02 0.079 4 0.157 0 40 1.575 20 0.787 80 3.150 60 2.362 50 50 mm 1.969 1.969 in non-glossy paper left right center operating point ? (mm in ) gray non-glossy paper lightness: 5 white non- glossy paper sensor l setting distance l (mm in ) 20 0.787 40 1.575 60 2.362 30 1.181 50 1.969 80 3.150 0 ?2 mm 0.079 in ?3 mm 0.118 in ?3 mm 0.118 in ?2 mm 0.079 in distance l (mm in ) cx-443 adjustable range re ective type setting distance: 25 mm 0.984 in ? sensing elds emitted beam setting distance: 50 mm 1.969 in ? correlation between color (50 50 mm 1.969 1.969 in construction paper) and sensing range correlation between material (50 50 mm 1.969 1.969 in ) and sensing range these bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white color. the sensing range also varies depending on material. 50 1.969 0 25 0.984 white non- glossy paper cardboard plywood black rubber gray non-glossy paper (lightness: 5) sensing range l (mm in ) 50 mm 1.969 in 25 mm 0.984 in 50 1.969 25 0.984 0 white yellow orange brown green black red blue gray sensing range l (mm in ) 50 mm 1.969 in 25 mm 0.984 in 20 0.787 40 1.575 60 2.362 30 1.181 50 1.969 80 3.150 0 ?6.2 mm 0.244 in ?5.9 mm 0.232 in ?5.3 mm 0.209 in ?6.5 mm 0.256 in distance l (mm in ) ? white non- glossy paper gray non-glossy paper lightness: 5 sensor 50 50 mm 1.969 1.969 in non-glossy paper l 4 0.157 2 0.079 02 0.079 4 0.157 0 40 1.575 20 0.787 80 3.150 60 2.362 left right center operating point ? (mm in ) setting distance l (mm in ) ? gray non-glossy paper lightness: 5 white non- glossy paper sensor 50 50 mm 1.969 1.969 in non-glossy paper l 2 0.079 02 0.079 4 0.157 right center operating point ? (mm in ) 4 0.157 0 10 0.394 20 0.787 30 1.181 40 1.575 left setting distance l (mm in ) these bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white color. the sensing range also varies depending on material. correlation between color (50 50 mm 1.969 1.969 in construction paper) and sensing range correlation between material (50 50 mm 1.969 1.969 in ) and sensing range these bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white non-glossy paper. 50 1.969 25 0.984 0 white yellow orange brown green black red blue gray sensing range l (mm in ) 50 mm 1.969 in 25 mm 0.984 in 50 1.969 0 25 0.984 white non- glossy paper cardboard plywood black rubber gray non-glossy paper (lightness: 5) sensing range l (mm in ) 50 mm 1.969 in 25 mm 0.984 in these bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white non-glossy paper.
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 247 compact photoelectric sensor cx-400 series cx-444 adjustable range re ective type sensing characteristics (typical) sensing elds emitted beam setting distance: 100 mm 3.937 in ? setting distance: 25 mm 0.984 in ? setting distance: 50 mm 1.969 in ? 0 10 0.394 20 0.787 30 1.181 40 1.575 sensor ? 10 0.394 5 0.197 05 0.197 10 0.394 left right center operating point ? (mm in ) setting distance l (mm in ) gray non-glossy paper lightness: 5 50 50 mm 1.969 1.969 in non-glossy paper white non- glossy paper l 0 20 0.787 40 1.575 60 2.362 80 3.150 l ? sensor 10 0.394 5 0.197 05 0.197 10 0.394 left right center operating point ? (mm in ) setting distance l (mm in ) gray non-glossy paper lightness: 5 white non- glossy paper 50 50 mm 1.969 1.969 in non-glossy paper 0 50 1.969 100 3.937 l ? sensor 10 0.394 5 0.197 05 0.197 10 0.394 left center operating point ? (mm in ) right setting distance l (mm in ) gray non-glossy paper lightness: 5 50 50 mm 1.969 1.969 in non-glossy paper white non- glossy paper 0 ?9 mm ?0.354 in ?8 mm ?0.315 in ?6.5 mm ?0.256 in ?5.3 mm ?0.209 in 20 0.787 80 3.150 100 3.937 50 1.969 distance l (mm in ) correlation between color (50 50 mm 1.969 1.969 in construction paper) and sensing range correlation between material (50 50 mm 1.969 1.969 in ) and sensing range these bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 100 mm 3.937 in and 50 mm 1.969 in long, respectively, with white non-glossy paper. these bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 100 mm 3.937 in and 50 mm 1.969 in long, respectively, with white color. the sensing range also varies depending on material. 100 3.937 50 1.969 0 100 mm 3.937 in 50 mm 1.969 in white yellow orange red brown green blue gray black sensing range l (mm in ) 100 mm 3.937 in 50 mm 1.969 in 0 100 3.937 50 1.969 white non- glossy paper cardboard plywood black rubber gray non-glossy paper (lightness: 5) sensing range l (mm in ) sensing elds cx-442 adjustable range re ective type setting distance: 300 mm 11.811 in ? setting distance: 100 mm 3.937 in ? setting distance: 200 mm 7.874 in ? emitted beam ? 10 0.394 5 0.197 05 0.197 10 0.394 0 50 1.969 100 3.937 gray non-glossy paper lightness: 5 sensor 50 50 mm 1.969 1.969 in non-glossy paper left right center operating point ? (mm in ) white non- glossy paper l setting distance l (mm in ) # ? 10 0.394 5 0.197 05 0.197 10 0.394 100 3.937 200 7.874 gray non-glossy paper lightness: 5 white non- glossy paper 50 50 mm 1.969 1.969 in non-glossy paper left right center operating point ? (mm in ) 0 l sensor setting distance l (mm in ) # ? 400 15.748 10 0.394 100 3.937 200 7.874 300 11.811 5 0.197 05 0.197 10 0.394 0 l sensor gray non-glossy paper lightness: 5 50 50 mm 1.969 1.969 in non-glossy paper left center operating point ? (mm in ) white non- glossy paper right setting distance l (mm in ) 1.181 30 400 15.748 0 15 mm 0.591 in 11 mm 0.433 in 9 mm 0.354 in ?8 mm ?0.315 in 100 3.937 300 11.811 200 7.874 distance l (mm in ) correlation between color (50 50 mm 1.969 1.969 in construction paper) and sensing range correlation between material (50 50 mm 1.969 1.969 in ) and sensing range these bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 300 mm 11.811 in , 200 mm 7.874 in and 100 mm 3.937 in long, respectively, with white non-glossy paper. these bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 300 mm 11.811 in , 200 mm 7.874 in and 100 mm 3.937 in long, respectively, with white color. the sensing range also varies depending on material. white yellow orange red brown green blue gray black 100 3.937 400 15.748 300 11.811 200 7.874 0 sensing range l (mm in ) 100 mm 3.937 in 200 mm 7.874 in 300 mm 11.811 in 0 100 3.937 400 15.748 300 11.811 white non- glossy paper cardboard plywood black rubber gray non-glossy paper (lightness: 5) 200 7.874 100 mm 3.937 in 200 mm 7.874 in 300 mm 11.811 in sensing range l (mm in )
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 248 precautions for proper use all models mounting the tightening torque should be 0.5 nm or less. ? others do not use during the initial transient time (50 ms) after the power supply is switched on. ? sensor mounting bracket (optional) m3 (length 12 mm 0.472 in ) screw with washers refer to p.986 ~ for general precautions. cx-49 ective type sensor (excluding cx-491 ) please take care of the following points when detecting materials having a gloss. ? retrore ective type sensor with polarizing lters (cx-491 ) if a shiny object is covered or wrapped with a transparent lm, such as those described below, the retrore ective type sensor with polarizing lters may not be able to detect it. in that case, follow the steps given below. ? example of sensing objects can wrapped by clear lm aluminum sheet covered by plastic lm gold or silver color (specular) label or wrapping paper ? ? ? steps tilt the sensor with respect to the sensing object while tting. reduce the sensitivity. increase the distance between the sensor and the sensing object. ? ? ? retrore ective type sensor for transparent object sensing (cx-48 ) optimum sensing is possible when the position of the transparent sensing object is set at the center of the sensor and the re ector. if the sensing position is set near the sensor or the re ector, the sensing may be unstable. in this case, set the sensing position at the center of the sensor and the reflector. ? 1 make l, shown in the diagram, suf ciently long. 2 install at an angle of 10 to 30 degrees to the sensing object. l 10 to 30 make l sufficiently long sensing object reflector glossy surface when the sensor detects an uneven plastic receptacle or glass bottle, the received-light amount may differ with the sensing position or direction. adjust the sensitivity after con rming the stable sensing condition by turning the sensing object, etc. when sensing pipe-shaped transparent sensing object, set it in a standing, not lying, position as shown in figure a. the sensor may fail to detect a lying object as shown in figure b. ? ? sensor reflector transparent sensing object reflector sensor a reflector sensor b cx-44 care must be taken regarding the sensor mounting direction with respect to the object?s direction of movement. ? do not make the sensor detect an object in this direction because it may cause unstable operation. sensing object sensing object sensing object when detecting a specular object (aluminum or copper foil, etc.) or an object having a glossy surface or coating, please take care that there are cases when the object may not be detected due to a change in angle, wrinkles on the object surface, etc. ? when a specular body is present below the sensor, use the sensor by tilting it slightly upwards to avoid wrong operation. ? specular face tilt if a specular body is present in the background, wrong operation may be caused due to a small change in the angle of the background body. in that case, install the sensor at an inclination and con rm the operation with the actual sensing object. ? correct correct incorrect incorrect correct incorrect correct never use this product as a sensing device for personnel protection. in case of using sensing devices for personnel protection, use products which meet laws and standards, such as osha, ansi or iec etc., for personnel protection applicable in each region or country. ? ? cx-48
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 249 compact photoelectric sensor cx-400 series cx-44 take care that there is a non-detectable area right in front of the sensor. depending on whether you select the bgs or fgs function, the output operation changes as follows. ? ? precautions for proper use refer to p.986 ~ for general precautions. when using the bgs function l-on d-on l-on d-on on off on off on off on off sensing range setting distance non-detectable area bgs fgs bgs / fgs functions this sensor incorporates bgs / fgs functions. select either bgs or fgs function depending on the positions of the background and sensing object. ? bgs function fgs function this function is used when the sensing object contacts the background or the sensing object is glossy, etc. ? distance adjustment when this product is used, be sure to carry out the distance adjustment. since the distance adjuster of this sensor is a 5-turn adjuster, when the point a and b is adjusted as explained in the table right, there may be more than 1 turn between the point a and b . therefore, make sure to remember the turns of both points to nd the optimum position. be sure to wire the sensing mode selection input (pink / 2) before distance adjustment. if the wiring is done after the distance adjustment, the sensing area is changed. ? ? ? turn the distance adjuster gradually and lightly with a ?minus? screwdriver (please arrange separately). in order to protect itself, the distance adjuster idles if turned fully. if the adjuster is idled when distance adjustment is done, carry out the adjustment again. ? this function is used when the sensing object is apart from the background. ? sensing object background sensing object background step description distance adjuster 1 turn the distance adjuster fully counterclockwise to the minimum sensing range position. ( cx-441 /443 /444 : 20 mm 0.787 in approx., cx-442 : 40 mm 1.575 in approx.) turn fully 2 place an object at the required distance from the sensor, turn the distance adjuster gradually clockwise, and nd out point a where the sensor changes to the detecting condition. a 3 remove the object, turn the adjuster clockwise further until the sensor goes into the detecting state again. once it has entered, turn the distance adjuster backward until the sensor returns to the non-detecting condition. this position is designated as point b . when the sensor does not go into the detecting condition even if the adjuster is turned fully clockwise, the position where the adjuster was fully turned is regarded as the point b . there may be more than 1 turn between point a and b , since this sensor incorporates a 5-turn adjuster. a b 4 the optimum position to stably detect objects is the center point between a and b . optimum position a b when using the fgs function others its distance adjuster is mechanically operated. do not drop; avoid other shocks. ? step description distance adjuster 1 turn the distance adjuster fully clockwise to the maximum sensing range position. ( cx-441 /443 : 50 mm 1.969 in approx., cx-444 : 100 mm 3.937 in approx., cx-442 : 300 mm 11.811 in approx.) turn fully 2 in the state where the sensor detects the background, turn the distance adjuster gradually counterclockwise, and nd out point a where the sensor changes to the non-detecting condition. a 3 place an object at the required distance from the sensor, turn the adjuster counterclockwise further until the sensor goes into the non-detecting condition again. once entered, turn the distance adjuster backward until the sensor returns to the detecting condition. this position is designated as point b . when the s ensor does not go into the non-detecting condition even if the adjuster is turned fully counterclockwise, the position where the adjuster was fully turned is regarded as the point b . there may be more than 1 turn between point a and b , since this sensor incorporates a 5-turn adjuster. a b 4 the optimum position to stably detect objects is the center point between a and b . optimum position a b follow only steps 1 and 2 . since the sensing point may change depending on the sensing object, be sure to check the operation with the actual sensing object. ?
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 250 notes: 1) not incorporated on the emitter. 2) it is the power indicator (green) on the emitter. sensor cx-41 sensor cx-41 notes: 1) not incorporated on the emitter. 2) it is the power indicator (green) on the emitter. 2.5 0.098 3 0.118 3.95 0.156 7.85 0.309 11.9 0.469 beam axis 11.2 0.441 operation indicator (orange)(note 2) stability indicator (green)(note 1) sensitivity adjuster (note 1) operation mode switch (note 1) 15.5 0.610 ? 3.7 ?0.146 cable, 2 m 6.562 ft long 25.4 1.000 2-m3 0.5 0.020 thru-hole threads ( ) 20 0.787 31 1.220 operation indicator (orange)(note 2) sensitivity adjuster (note 1) 3.95 0.156 7.85 0.309 11.9 0.469 2.5 0.098 3 0.118 42.5 1.673 35.5 1.398 31 1.220 25.4 1.000 15.5 0.610 stability indicator (green)(note 1) beam axis 11.2 0.441 ?9.4 ?0.370 operation mode switch (note 1) m8 connector 2-m3 0.5 0.020 thru-hole threads 20 0.787 ( ) sensor cx-41 notes: 1) not incorporated on the emitter. 2) it is the power indicator (green) on the emitter. 3.95 0.156 7.85 0.309 11.9 0.469 operation indicator (orange)(note 2) stability indicator (green)(note 1) sensitivity adjuster (note 1) operation mode switch (note 1) 3 0.118 2.5 0.098 m12 connector 31 1.220 25.4 1.000 15.5 0.610 ?3.7 ?0.146 cable beam axis 11.2 0.441 2-m3 0.5 0.020 thru-hole threads 300 11.811 ( ) ( ) ( ) 44 1.732 20 0.787 sensor cx-49 3.95 0.156 7.85 0.309 11.9 0.469 operation indicator (orange) stability indicator (green) sensitivity adjuster operation mode switch 4 0.157 2.5 0.098 3 0.118 11.2 0.441 beam-receiving part 15.5 0.610 center of sensing 25.4 1.000 4 0.157 beam-emitting part 2-m3 0.5 0.020 thru-hole threads ?3.7 ?0.146 cable, 2 m 6.562 ft long 31 1.220 20 0.787 ( ) sensor cx-49 ( ) 3 0.118 2.5 0.098 11.9 0.469 7.85 0.309 3.95 0.156 sensitivity adjuster operation indicator (orange) stability indicator (green) operation mode switch 25.4 1.000 15.5 0.610 2-m3 0.5 0.020 thru-hole threads center of sensing m8 connector 11.2 0.441 ?9.4 ?0.370 beam-emitting part beam-receiving part 4 0.157 4 0.157 42.5 1.673 20 0.787 35.5 1.398 31 1.220 sensor cx-49 ( ) 2.5 0.098 20 0.787 11.9 0.469 7.85 0.309 3.95 0.156 operation mode switch sensitivity adjuster operation indicator (orange) stability indicator (green) center of sensing 2-m3 0.5 0.020 thru-hole threads beam-emitting part beam-receiving part 15.5 0.610 4 0.157 4 0.157 11.2 0.441 3 0.118 ?3.7 ?0.146 cable m12 connector ( ) 44 1.732 ( ) 300 11.811 31 1.220 25.4 1.000 dimensions (unit: mm in ) the cad data in the dimensions can be downloaded from the sunx website: http://www.sunx.com
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 251 compact photoelectric sensor cx-400 series sensor cx-44 sensor cx-44 4 0.157 8.2 0.323 12.5 0.492 stability indicator (green) operation mode switch distance adjuster (5-turn) operation indicator (orange) 3 0.118 0.9 0.035 20 0.787 2.8 0.110 2 0.079 11.2 0.441 2-m3 0.5 0.020 thru-hole threads 22 0.866 beam- receiving part beam- emitting part center of sensing ?3.7 ?0.146 cable, 2 m 6.562 ft long 31 1.220 25.4 1.000 22 0.866 ?9.4 ?0.370 2-m3 0.5 0.020 thru-hole threads 11.2 0.441 beam- receiving part beam- emitting part center of sensing 31 1.220 25.4 1.000 42.5 1.673 35.5 1.398 2.8 0.110 2 0.079 3 0.118 0.9 0.035 m8 connector 4 0.157 8.2 0.323 12.5 0.492 stability indicator (green) operation mode switch distance adjuster (5-turn) operation indicator (orange) 20 0.787 rf-230 re ector (accessory for the retrore ective type sensor) rf-220 re ector (optional) rf-210 re ector (optional) 2-?4.6 ? 0.181 mounting holes 50.3 1.980 40 1.575 5 0.197 8.3 0.327 3.3 0.130 10 0.394 59.3 2.335 49.3 1.941 ( ) 30 1.181 35.3 1.390 42.3 1.665 34.3 1.350 25 0.984 2-?3.6 ? 0.142 mounting holes 4 0.157 8 0.315 8.3 0.327 3.3 0.130 21 0.827 ( ) 33.3 1.311 reflector m3 nut mounting holes (for mounting at the back) base 25 0.984 3.2 0.126 10 0.394 2-?3.4 ? 0.134 thru-holes (for mounting at the side) (for mounting at the back) 2-?3.4 ? 0.134 holes, 6 0.236 deep (for mounting at the side) 2-m3 nut mounting holes 12.8 0.504 11 0.433 rf-11 re ective tape (optional) rf-12 re ective tape (optional) 8 0.315 28 1.102 30 1.181 adhesive tape effective reflecting surface 0.7 0.028 ( ) ( ) 6 0.236 ( ) 30 1.181 0.7 0.028 28 1.102 25 0.984 23 0.906 adhesive tape effective reflecting surface ( ) 0.5 0.020 30 1.181 30 1.181 ( ) reflective surface (acrylic) rear surface pressure-sensitive adhesive rf-13 re ective tape (optional) dimensions (unit: mm in ) the cad data in the dimensions can be downloaded from the sunx website: http://www.sunx.com material: acrylic (re ector) abs (base) material: acrylic (re ector) abs (base) material: acrylic (re ector) abs (base) two m3 (length 8 mm 0.315 in ) screws with washers and two nuts are attached. material: acrylic material: acrylic
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 252 ms-cx2-1 sensor mounting bracket (optional) assembly dimensions mounting drawing with the receiver of cx-41 ms-cx2-2 sensor mounting bracket (optional) assembly dimensions mounting drawing with the receiver of cx-41 ms-cx2-4 sensor mounting bracket (optional) assembly dimensions mounting drawing with the receiver of cx-41 3.4 0.134 8 0.315 14 0.551 5 0.197 3 0.118 3.4 0.134 14 10 0.394 7 2-?3.4 ? 0.134 holes (for rf-210 ) 3.4 0.134 12.5 0.492 t 1.2 t 0.047 12 0.472 22 0.866 15 0.591 20 0.787 r25 r0.984 25 0.984 42.5 1.673 r12 r0.472 beam axis 9.5 0.374 25 0.984 12.3 0.484 t 1.2 t 0.047 25.4 1.000 0.4 0.016 7 13.6 0.535 3.4 0.134 3.4 0.134 5 0.197 3 0.118 14 12 0.472 r12 r0.472 0.5 0.020 31 1.220 42.5 1.673 ( ) 22 0.866 25.2 0.992 20 0.787 15.8 0.622 t 2 t 0.079 5 0.197 4.5 0.177 4.5 0.177 14 7.8 0.307 4.5 0.177 4 0.157 12 0.472 7.8 0.307 7 0.276 23 0.906 10 0.394 8-?3.4 ?0.134 holes r12 r0.472 14 0.551 7 0.276 14 0.551 36 1.417 55 2.165 22 0.866 25 0.984 15.5 0.610 ( ) beam axis 15.8 0.622 8.2 0.323 t 2 t 0.079 3.6 0.142 4 0.157 14 0.551 4.5 0.177 4.5 0.177 12 0.472 5 0.197 14 r12 r0.472 7 0.276 4.5 0.177 4 0.157 8.2 0.323 28 1.102 55 2.165 36 1.417 22 0.866 25.4 1.000 15.3 0.602 3.4 0.134 3.4 0.134 4 0.157 7 14 ?25 ?0.984 r25 r0.984 sensor 18 0.709 13 0.512 t 2.5 t 0.098 6.2 0.244 r9.5 r0.374 sensor 29 1.142 19 0.748 5.5 0.217 5.5 0.217 6 0.236 7 0.276 20 40 ?55 ?2.165 ?39 ?1.535 25 0.984 25 0.984 25 0.984 19 0.748 46 1.811 20 40 7 0.276 0.9 0.035 13 0.512 11.2 0.441 0.9 0.035 12.3 0.484 25 0.984 t 2.5 t 0.098 beam axis 46 1.811 sensor sensor ?55 ? 2.165 ?39 ? 1.535 29 1.142 18 0.709 25.4 1.000 dimensions (unit: mm in ) the cad data in the dimensions can be downloaded from the sunx website: http://www.sunx.com material: stainless steel (sus304) two m3 (length 12 mm 0.472 in ) screws with washers are attached. material: stainless steel (sus304) two m3 (length 12 mm 0.472 in ) screws with washers are attached. material: stainless steel (sus304) two m3 (length 14 mm 0.551 in ) screws with washers are attached.
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in 253 compact photoelectric sensor cx-400 series ms-cx2-5 sensor mounting bracket (optional) assembly dimensions mounting drawing with the receiver of cx-41 3.4 0.134 3.4 0.134 3.5 0.138 6.5 0.256 5 0.197 7 15 0.591 t 1.5 t 0.059 8 0.315 5 0.197 7.9 0.311 7 0.276 45 1.772 18.9 0.744 37 1.457 20 0.787 19 0.748 25 0.984 19 0.748 r19 r 0.748 r25 r0.984 t 1.5 t 0.059 25.4 1.000 beam axis 7 r25 r0.984 7 0.276 20 0.787 6.5 0.256 5 0.197 5 0.197 7.9 0.311 20.6 0.811 26.2 1.031 45 1.772 18.9 0.744 37 1.457 15 0.591 ms-cx-3 sensor mounting bracket (optional) t 1.2 t 0.047 20.5 0.807 3.5 0.138 3.4 0.134 3.4 0.134 10 r25 r0.984 5 0.197 3.4 0.134 10 5 0.197 15 0.591 14 0.551 8 0.315 3.4 0.134 6 0.236 8.5 0.335 6 0.236 30 1.181 35 1.378 25 0.984 18 0.709 r25 r0.984 assembly dimensions mounting drawing with the receiver of cx-41 13.6 0.535 3.4 0.134 8 0.315 14 0.551 6 0.236 9 0.354 8.5 0.335 18 0.709 beam axis 0.5 0.020 3.5 0.138 4.8 0.189 t 1.2 t 0.047 0.4 0.016 10 25.2 0.992 11.2 0.441 6 0.236 31 1.220 30 1.181 25.4 1.000 35 1.378 ( ) 20 0.787 ms-rf21-1 re ector mounting bracket for rf-210 (optional) assembly dimensions 12.5 0.492 t 1.2 t 0.047 13 0.512 ?25 ?0.984 16 0.630 10 0.394 3.5 0.138 3.2 0.126 r7.5 r0.295 25 0.984 46 1.811 20 23 0.906 50 1.969 5.5 0.217 ?36 ?1.417 30 46 1.811 25 0.984 13 0.512 10 0.394 20 50 1.969 ?36 ?1.417 30 23 0.906 5.5 0.217 dimensions (unit: mm in ) the cad data in the dimensions can be downloaded from the sunx website: http://www.sunx.com material: stainless steel (sus304) two m3 (length 12 mm 0.472 in ) screws with washers are attached. material: stainless steel (sus304) two m3 (length 12 mm 0.472 in ) screws with washers are attached. material: stainless steel (sus304) two m3 (length 12 mm 0.472 in ) screws with washers are attached.
fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers photo- electric sensors selection guide amplifier built-in ex-10 cx-400 ex-20 ex-30 ex-40 eq-30 eq-500 mq-w rx-ls200 rx cy px-2 rt-610 amplifier- separated power supply built-in nx5 vf su-7 / sh ss-a5 / sh other products cx-400 ampli er built-in compact photoelectric sensor cx-400 series 254 ms-rf22 re ector mounting bracket for rf-220 (optional) assembly dimensions 4.5 0.177 10 0.394 11 0.433 25 0.984 35 1.378 4 0.157 16 0.630 10 0.394 6 0.236 8 0.315 44 1.732 20 0.787 t 1.6 t 0.063 8-m3 0.5 0.020 thru-hole threads 25 0.984 4.5 0.177 25 0.984 10 0.394 28.3 1.114 8.3 0.327 34.3 1.350 8 0.315 4 0.157 21 0.827 35.3 1.390 44.3 1.744 6 0.236 27 1.063 t 1.6 t 0.063 19.3 0.760 ( ) ( ) dimensions (unit: mm in ) the cad data in the dimensions can be downloaded from the sunx website: http://www.sunx.com material: cold rolled carbon steel (spcc) (uni-chrome plated) two m3 (length 8 mm 0.315 in ) screws with washers are attached. ms-rf23 re ector mounting bracket for rf-230 (optional) assembly dimensions 40 1.575 4.5 0.177 3 0.118 10 0.394 11 0.433 50 1.969 40 1.575 5 0.197 16 0.630 15 0.591 18 0.709 7 0.276 20 0.787 t 2 t 0.079 8-m4 0.7 0.028 thru-hole threads 26 1.024 12 0.472 35 1.378 3 0.118 61 2.402 ( ) ( ) 28 1.102 ( ) 40 1.575 4.5 0.177 28.3 1.114 19.3 0.760 8.3 0.327 10 0.394 50.3 1.980 49.3 1.941 5 0.197 t 2 t 0.079 10 0.394 30 1.181 61.3 2.413 7 0.276 37 1.457 40 1.575 ( ) ( ) material: cold rolled carbon steel (spcc) (uni-chrome plated) two m4 (length 10 mm 0.394 in ) screws with washers are attached.


▲Up To Search▲   

 
Price & Availability of CX-411

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X